| Marka/Model | Kod | Açıklama |
| AİRFEL ALIXIA | 40 | 50 60 70 80 90 AŞIRI ISI |
| AİRFEL ALIXIA | 0 | 0 YETERSİZ SU VEYA SU BASINCI |
| AİRFEL ALIXIA | 0 | 0 0 KALORİFER NTC |
| AİRFEL ALIXIA | 0 | 0 0 SICAK SU NTC |
| AİRFEL ALIXIA | 0 | 0 MİCRO İŞLEMCİ PROGRAM |
| AİRFEL ALIXIA | 0 | 0 ANA KART İLE EKRAN ARASINDA İLETİŞİM KOPMASI YADA UYMAMASI |
| AİRFEL ALIXIA | 0 | 0 5 DEFADAN FAZLA RESET YAPIMASI |
| AİRFEL ALIXIA | 0 | 0 0 0 0 ELEKTRONİK KART |
| AİRFEL ALIXIA | 0 | 0 ATEŞLEME ARIZASI |
| AİRFEL ALIXIA | 0 | 0 YANLIŞ İYON ALGILAMA |
| AİRFEL ALIXIA | 0 | 0 0 0 ALEV KOPMASI İYON |
| AİRFEL ALIXIA | 0 | 0 0 0 HAVA PROSESTAT FAN ELEKTRONİK KART |
| AİRFEL COMPY-MX | 30 | 40 50 60 70 80 ARIZA |
| AİRFEL COMPY-MX | 0 | 0 0 0 0 AŞIRI ISI LİMİT NTC BASINÇ POMPA |
| AİRFEL COMPY-MX | 0 | 0 0 0 ALEV YOKLUĞU İYON |
| AİRFEL COMPY-MX | 0 | 0 0 0 DONMA KORUMA |
| AİRFEL COMPY-MX | 0 | 0 0 POMPA BLOKAJ KURU YANMA |
| AİRFEL COMPY-MX | 0 | 0 0 KALORİFER GİDİŞ NTC |
| AİRFEL COMPY-MX | 0 | 0 0 0 KALORİFER GİDİŞ NTC |
| AİRFEL COMPY-MX | 0 | 0 0 KALORİFER DÖNÜŞ NTC |
| AİRFEL COMPY-MX | 0 | 0 0 0 ELEKTRİK KABLO VOLTAJ VEYA KARTIN ÜSTÜNDEKİ SİGORTALAR |
| AİRFEL COMPY-MX | 0 | 0 0 FAN PROSESTAT ELEKTRONİK KART |
| AİRFEL COMPY-MX | 0 | 0 EKRAN KARTI UYUMSUZLUĞU |
| AİRFEL COMPY-MX | 0 | 0 0 0 0 ANAKART İLETİŞİM VE EKRAN KART UYUMSUZLUĞU |
| İNTEGRİTY-AUER MAXİMA | LP | SU BASINCI |
| İNTEGRİTY-AUER MAXİMA | HL | LİMİT |
| İNTEGRİTY-AUER MAXİMA | AF | FAN PROSESTAT KART |
| İNTEGRİTY-AUER MAXİMA | Hb | KALORİFER SENSÖR |
| İNTEGRİTY-AUER MAXİMA | db | SICAK SU SENSÖR |
| İNTEGRİTY-AUER MAXİMA | Bc | B2-B3-B4FAN PROSESTAD KART |
| İNTEGRİTY-AUER MAXİMA | G1 | GAZ VALFİ ALEV YOKLUĞU |
| İNTEGRİTY-AUER MAXİMA | A5 | FAN PROSESTAD KART |
| İNTEGRİTY-AUER MAXİMA | Fr | DONMA KORUMA |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A01 | AŞIRI ISI LİMİT E13 KALORİFER DÖNÜŞ SENSÖRÜ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A03 | ALEV OLUŞUM GECİKMESİ E14 KALORİFER DÖNÜŞ SENSÖRÜ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A36 | TANIMSIZ E15 HARİCİ SENSÖR HATALI |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A37 | İLETİŞİM HATASI E16 HARİCİ SENSÖR KISA DEVRE |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A39 | İŞLEMCİ HATASI E18 ALEV OLUŞMAMA TEKRAR DENEME |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A40 | İŞLEMCİ HATASI E20 İYONİZASYON ALEV KOPMASI |
| AİRFEL MİRA GREEN-NİAGARA GREEN | A41 | FAN HATASI E22 SICAK SU SENSÖRÜ (DALDIRMA TİP) |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E02 | TANIMSIZ E25 BOYLER SENSÖRÜ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E04 | ALEV OLUŞMAMA,TEKRAR DENEME E26 BOYLER SENSÖRÜ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E05 | POMPA DON KORUMA E29 ODA TERMOSTADI KISA DEVRE |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E06 | BRÜLÖR DON KORUNMA E30 ODA TERMOSTADI AÇIK DEVRE |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E07 | POMPA SİRKÜLASYON HATASI E33 YERDEN ISITMA TERMOSTADI AÇIK DEVRE |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E08 | POMPA SİRKÜLASYON HATASI E34 TANIMSIZ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E09 | SICAK SU SENSÖR E35 TANIMSIZ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E10 | SICAK SU SENSÖR E36 TANIMSIZ |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E11 | KALORİFER GİDİŞ SENSÖRÜ E37 ANAKART İLETİŞİM HATASI |
| AİRFEL MİRA GREEN-NİAGARA GREEN | E12 | KALORİFER GİDİŞ SENSÖRÜ E38 RESETE 15 DAKİKADA 5 DEFA BASILMASI |
| AUER MAXİMAX | C1 | 05 |
| AUER MAXİMAX | C1 | 10 LİMİT TERMOSTAD HATASI |
| AUER MAXİMAX | C1 | 11 LİMİT ARIZASI |
| AUER MAXİMAX | C1 | 17 SU BASINÇ YÜKSEK |
| AUER MAXİMAX | C1 | 18 SU BASINCI DÜŞÜK |
| AUER MAXİMAX | C1 | 20 KALORİFER GİDİŞ SENSÖRÜ HATASI |
| AUER MAXİMAX | C1 | 28 BACA GAZI SENSÖRÜ |
| AUER MAXİMAX | C1 | 33 ATEŞLEME HATASI |
| AUER MAXİMAX | C1 | 40 KALORİFER DÖNÜŞ SENSÖRÜ |
| AUER MAXİMAX | C1 | 50 SICAK SU SENSÖRÜ |
| AUER MAXİMAX | C1 | 54 KALORİFER SENSÖRLERİ ARASINDAKİ ISI FARKI |
| AUER MAXİMAX | C1 | 78 BASINÇ SENSÖRÜ |
| ALARKO TRENDY D-HARMONY D | F0 | SU BASINÇ ARIZASI |
| ALARKO TRENDY D-HARMONY D | F1 | LİMİT |
| ALARKO TRENDY D-HARMONY D | F2 | SICAK SU SENSÖR |
| ALARKO TRENDY D-HARMONY D | F3 | KALORİFER SENSÖR |
| ALARKO TRENDY D-HARMONY D | F4 | İYON ALEV YOKLUĞU |
| ALARKO TRENDY D-HARMONY D | F5 | FAN PROSESTAT KART |
| ARÇELİK 20 EK RİELLO-PREMİX | A01 | ALEV YOKLUĞU İYON |
| ARÇELİK 20 EK RİELLO-PREMİX | A02 | LİMİT |
| ARÇELİK 20 EK RİELLO-PREMİX | A03 | FAN PROSESTAT KART |
| ARÇELİK 20 EK RİELLO-PREMİX | A04 | BASINÇ |
| ARÇELİK 20 EK RİELLO-PREMİX | A06 | SICAK SU SENSÖR |
| ARÇELİK 20 EK RİELLO-PREMİX | A07 | KALORİFER SERNSÖR |
| ARÇELİK 20 EK RİELLO-PREMİX | A08 | DÖNÜŞ SENSÖRÜ ARIZASI |
| ARÇELİK 20 EK RİELLO-PREMİX | A09 | BACA GAZI (ESANJÖR)SENSÖRÜ |
| ARÇELİK 20 EK RİELLO-PREMİX | A11 | YANLIŞ İYON |
| ARÇELİK 20 EK RİELLO-PREMİX | A77 | DÜŞÜK ISI DONMA KORUMA |
| ARÇELİK ALTUS | E01 | ALEV YOKLUĞU İYON |
| ARÇELİK ALTUS | E02 | AŞIRI ISI LİMİT |
| ARÇELİK ALTUS | E03 | FAN PROSESTAT ELEKTRONİK KART |
| ARÇELİK ALTUS | E04 | SU BASINÇ |
| ARÇELİK ALTUS | E05 | GAZ BASINÇ GAZ VALFİ |
| ARÇELİK ALTUS | E06 | SICAK SU SENSÖR |
| ARÇELİK ALTUS | E07 | KALORİFER SENSÖR |
| ARÇELİK ALTUS | E08 | AŞIRI ISI LİMİT |
| ARÇELİK ALTUS | E09 | ANAKARTTAKİ SİVİÇLERİN KONUM HATASI |
| ARÇELİK ALTUS | E0 | DAHİLİ İLETİŞİM HATASI |
| ARÇELİK ALTUS | EA | KALORİFER DÖNÜŞ SENÖRÜ |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 01 AŞIRI ISI 2 01 SICAk SU NTC 5 01 İYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 02 LİMİT 2 02 BOYLER NTC 5 02 YANLIŞ ALEV |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 03 POMPA 2 03 BOYLER NTC 5 04 İYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 04 POMPA 2 04 GÜNEŞ KOLLEKTÖR NTC 5 P1 İYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 05 POMPA 2 05 GÜNEŞ KOLLEKTÖR NTC 5 P2 İYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 06 POMPA 2 07 GÜNEŞ KOLLEKTÖR NTC 5 P3 İYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 07 POMPA 2 08 GÜNEŞ KOLLEKTÖR NTC 5 P4 İYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 08 DÜŞÜK BASINÇ 2 09 BOYLER LİMİT HAVA SİRKÜLASYON |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 09 YÜKSEK BASINÇ PCP – GPUI 6 01 BACA SENSÖR |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 10 DÖNÜŞ NTC 3 01 EPROM 6 04 FAN DEVİR |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 11 SU BASINÇ 3 02 İLTİŞİM 6 10 PROSESTAT |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 12 DÖNÜŞ NTC 3 03 DAHİLİ 6 12 FAN SİGORTA |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 14 DIŞ SENSÖR 3 04 FAZLA RESETLEME 6 P1 PROSESTAT |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 16 YERDEN ISITMA SENSÖR 3 05 DAHİLİ 6 P2 PROSESTAT |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | 18 MERKEZİ ISITMA SENSÖR 3 06 DAHİLİ 6 P4 FAN DEVİR |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P1 POMPA ÇEVRE KONTROL 7 02 BÖLGESEL NTC |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P2 POMPA 4 01 MODEM 7 03 BÖLGESEL NTC |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P3 POMPA 4 02 MODEM 7 04 BÖLGESEL NTC |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P4 DÜŞÜK BASINÇ 4 03 SİM KART 7 05 BÖLGESEL NTC |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P5 YETERSİZ SU 4 04 MODEM 7 06 BÖLGESEL NTC |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P6 YETERSİZ BASINÇ 4 05 MODEM 7 07 BÖLGESEL NTC |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P7 OTOMATİK DOLDURMA 4 06 MODEM |
| ARİSTON CLASS-CLASS PREMİUM- | 1 | P8 OTOMATİK DOLDURMA 4 07 ODA SENSÖRÜ |
| ARİSTON EGİS | 40 | 50 60 70 80 90 AŞIRI ISI |
| ARİSTON EGİS | 0 | 0 YETERSİZ SU VEYA SU BASINCI |
| ARİSTON EGİS | 0 | 0 0 KALORİFER NTC |
| ARİSTON EGİS | 0 | 0 0 SICAK SU NTC |
| ARİSTON EGİS | 0 | 0 MİCRO İŞLEMCİ PROGRAM |
| ARİSTON EGİS | 0 | 0 ANA KART İLE EKRAN ARASINDA İLETİŞİM KOPMASI YADA UYMAMASI |
| ARİSTON EGİS | 0 | 0 5 DEFADAN FAZLA RESET YAPIMASI |
| ARİSTON EGİS | 0 | 0 0 0 0 ELEKTRONİK KART |
| ARİSTON EGİS | 0 | 0 ATEŞLEME ARIZASI |
| ARİSTON EGİS | 0 | 0 YANLIŞ İYON ALGILAMA |
| ARİSTON EGİS | 0 | 0 0 0 ALEV KOPMASI İYON |
| ARİSTON EGİS | 0 | 0 0 0 HAVA PROSESTAT FAN ELEKTRONİK KART |
| ARİSTON MİCRAGENUS PLUS | A01 | İYON ARIZASI |
| ARİSTON MİCRAGENUS PLUS | A03 | LİMİT AŞIRI ISI |
| ARİSTON MİCRAGENUS PLUS | A97 | DAHİLİ HATA |
| ARİSTON MİCRAGENUS PLUS | A98 | DAHİLİ HATA |
| ARİSTON MİCRAGENUS PLUS | A99 | DAHİLİ HATA |
| ARİSTON MİCRAGENUS PLUS | E02 | SU BASINÇ HATASI |
| ARİSTON MİCRAGENUS PLUS | E04 | SICAK SU SENSÖR |
| ARİSTON MİCRAGENUS PLUS | E05 | SICAK SU SENSÖR |
| ARİSTON MİCRAGENUS PLUS | E06 | KALORİFER SENSÖR |
| ARİSTON MİCRAGENUS PLUS | E07 | KALORİFER SENSÖR |
| ARİSTON MİCRAGENUS PLUS | E08 | KALORİFER SENSÖR |
| ARİSTON MİCRAGENUS PLUS | E09 | KALORİFER SENSÖR |
| ARİSTON MİCRAGENUS PLUS | E20 | YANLIŞ İYON |
| ARİSTON MİCRAGENUS PLUS | E21 | ELEKTRİK BAĞLANTI VE VOLTAJ |
| ARİSTON MİCRAGENUS PLUS | E32 | FAN PROSESTAT KART |
| ARİSTON MİCRAGENUS PLUS | E33 | FAN PROSESTAT KART |
| ARİSTON MİCRAGENUS PLUS | E34 | FAN PROSESTAT KART |
| ARİSTON MİCRAGENUS PLUS | E68 | ATIK GAZ SENSÖRÜ |
| ARİSTON MİCRAGENUS PLUS | E80 | ODA TERMOSTAD SENSÖRÜ |
| ARİSTON MİCRAGENUS PLUS | E99 | 5 KERE RESETE BASMA |
| ARİSTON MİCRAGENUS PLUS | S30 | DIŞ ORTAM SENSÖRÜ |
| ARİSTON MİCRAGENUS PLUS | S31 | DIŞ ORTAM SENSÖRÜ |
| BARETTA SUPER EXCLUSİVE | 0.1 | İYON |
| BARETTA SUPER EXCLUSİVE | 0.2 | LİMİT |
| BARETTA SUPER EXCLUSİVE | 0.3 | FAN PROSESTAT |
| BARETTA SUPER EXCLUSİVE | 0.4 | SU BASINÇ |
| BARETTA SUPER EXCLUSİVE | 0.5 | UZAKTAN KUMANDA |
| BARETTA SUPER EXCLUSİVE | 0.6 | SICAK SU SENSÖR |
| BARETTA SUPER EXCLUSİVE | 0.7 | KALORİFER SENSÖR |
| BAYKAN | E01 | 80° |
| BAYKAN | E02 | 60° |
| BAYKAN | E03 | 30° |
| BAYKAN | E04 | 40° |
| BAYKAN | E05 | 30+40° |
| BAYKAN | E06 | 70° |
| BAYKAN | E07 | 60+80° |
| BAYKAN | E08 | 50° |
| BAYKAN | E09 | 70° |
| BAYMAK BAXİ ECO 3-ECO 4 | E01 | BAŞARISIZ ATEŞLEME |
| BAYMAK BAXİ ECO 3-ECO 4 | E02 | LİMİT |
| BAYMAK BAXİ ECO 3-ECO 4 | E03 | FAN PROSESTAT KART |
| BAYMAK BAXİ ECO 3-ECO 4 | E04 | KALORİFER SENSÖR |
| BAYMAK BAXİ ECO 3-ECO 4 | E05 | SICAK SU SENSÖR |
| BAYMAK BAXİ ECO 3-ECO 4 | E10 | SU BASINÇ |
| BAYMAK BAXİ ECO 3-ECO 4 | E25/26 | POMPA BLOKAJ |
| BAYMAK BAXİ ECO 3-ECO 4 | E96 | VOLTAJ KART |
| BAYMAK BAXİ ECO 3-ECO 4 | E98 | DAHİLİ KART HATASI |
| BAYMAK BAXİ ECO 5 | A01 | Başarısız ateşleme |
| BAYMAK BAXİ ECO 5 | A03 | Emn. termostatı arızası |
| BAYMAK BAXİ ECO 5 | E03 | Hava basınç anahtarı arızası |
| BAYMAK BAXİ ECO 5 | E05 | Çıkıs suyu sensor arızası |
| BAYMAK BAXİ ECO 5 | E06 | Kullanım suyu sensor arızası |
| BAYMAK BAXİ ECO 5 | E10 | Düşük su basıncı arızası |
| BAYMAK BAXİ ECO 5 | E26 | Aşırı ısınma arızası muhtemel pompa |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E01 | BAŞARISIZ ATEŞLEME |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E02 | LİMİT |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E03 | FAN PROSESTAT KART |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E04 | KALORİFER SENSÖR |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E05 | SICAK SU SENSÖR |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E10 | SU BASINÇ |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E25/26 | POMPA BLOKAJ |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E96 | VOLTAJ KART |
| BAYMAK BAXİ LUNA 3-LUNA 4 | E98 | DAHİLİ KART HATASI |
| BAYMAK BAXİ LUNA 5 | E01 | İYON F02 Hatalı alev oluşumu |
| BAYMAK BAXİ LUNA 5 | E02 | İYON F13 Kombi kilitlenme |
| BAYMAK BAXİ LUNA 5 | E03 | AŞIRI ISI LİMİT F22 Düşük voltaj arızası |
| BAYMAK BAXİ LUNA 5 | E04 | FAN PROSETAT F23 Hava basınç anahtarı arızası |
| BAYMAK BAXİ LUNA 5 | E05 | FAN PROSETAT F25 Elektronik kart arızası |
| BAYMAK BAXİ LUNA 5 | E06 | FAN PROSETAT F31 Merkezi ısıtma NTC arızası |
| BAYMAK BAXİ LUNA 5 | E07 | BACA TERMOSTADI F32 Dış hava sensörü arızası |
| BAYMAK BAXİ LUNA 5 | E08 | GAZ VALFİ F33 Kullanım suyu NTC arızası |
| BAYMAK BAXİ LUNA 5 | E09 | GAZ VALFİ F37 Düşük su basıncı arızası |
| BAYMAK BAXİ LUNA 5 | E12 | DAHİLİ ANA KART F40/47 Su basınç anahtarı arızası |
| BAYMAK BAXİ LUNA 5 | E21 | DAHİLİ ANA KART F59 Gaz valfi modulasyon bobin arızası |
| BAYMAK BAXİ LUNA 5 | E82 | GAZ VALFİ İYON |
| BAYMAK DUOTECH – LAMBERT | E01 | İYON ALEV YOKLUĞU F34 DÜŞÜK VOLTAJ HATASI |
| BAYMAK DUOTECH – LAMBERT | E02 | İYON ALEV YOKLUĞU F35 KALORİFER SENSÖR |
| BAYMAK DUOTECH – LAMBERT | E03 | AŞIRI ISI LİMİT F37 SU BASINÇ |
| BAYMAK DUOTECH – LAMBERT | E05 | FAN GERİ BESLEME F39 DIŞ HAVA SENSÖRÜ |
| BAYMAK DUOTECH – LAMBERT | E08 | ATEŞLEME HATASI F40 YÜKSEK SU BASINÇ |
| BAYMAK DUOTECH – LAMBERT | E09 | GAZ VALFİ F41/42/43 |
| BAYMAK DUOTECH – LAMBERT | E12 | EPROM F50 BOYLER SENSÖRÜ |
| BAYMAK DUOTECH – LAMBERT | E21 | DAHİLİ KART HATASI F51 PT1000 BOYLER SENSÖRÜ |
| BAYMAK DUOTECH – LAMBERT | E33 | DÖNÜŞ SENSÖR F52 SICAK SU SENSÖRÜ |
| BAYMAK DUOTECH – LAMBERT | E35 | ÇIKIŞ SENSÖR F53 TERMAL SİGORTA |
| BAYMAK DUOTECH – LAMBERT | F13 | RESET KİTLEMESİ F81 SENSÖRLER ARASI ISI FARKI |
| BAYMAK DUATECH GRUPPO | E1 | İYON |
| BAYMAK DUATECH GRUPPO | E3 | KALORİFER SENSÖR |
| BAYMAK DUATECH GRUPPO | E4 | SICAK SU SENSÖR |
| BAYMAK DUATECH GRUPPO | E5 | FAN GERİ BESLEME |
| BAYMAK DUATECH GRUPPO | E6 | AŞIRI ISI LİMİT |
| BAYMAK DUATECH GRUPPO | E8 | DÜŞÜK BASINÇ |
| BAYMAK DUATECH GRUPPO | E9 | LİMİT |
| BAYMAK DUATECH GRUPPO | E10 | YÜKDSEK BASINÇ |
| BAYMAK DUATECH GRUPPO | E12 | RESET KİTLEMESİ |
| BAYMAK DUATECH GRUPPO | E13 | EPROM |
| BAYMAK DUATECH GRUPPO | E16 | BACA TERMOSTAD |
| BAYMAK DUATECH GRUPPO | E23 | DIŞ HAVA TERMOSTAD |
| BAYMAK DUATECH GRUPPO | E25 | ANA ESANJÖR UYARISI |
| BAYMAK DUATECH GRUPPO | E26 | VOLTAJ BESLEME |
| BAYMAK DUATECH LUNA 3 | E10 | DIŞ HAVA SENSÖRÜ |
| BAYMAK DUATECH LUNA 3 | E20 | KALORİFER SENSÖRÜ |
| BAYMAK DUATECH LUNA 3 | E28 | BACA SENSÖRÜ |
| BAYMAK DUATECH LUNA 3 | E50 | SICAK SU SENSÖRÜ |
| BAYMAK DUATECH LUNA 3 | E110 | LİMİT AŞIRI ISI |
| BAYMAK DUATECH LUNA 3 | E119 | SU BASINÇ |
| BAYMAK DUATECH LUNA 3 | E125 | KURU YANMA SİRKÜLASYON |
| BAYMAK DUATECH LUNA 3 | E130 | BACA SENSÖRÜ |
| BAYMAK DUATECH LUNA 3 | E133 | ALEV YOKLUĞU İYON |
| BAYMAK DUATECH LUNA 3 | E151 | HADİLİ ANA KART |
| BAYMAK DUATECH LUNA 3 | E156 | DÜŞÜK – YÜKSEK VOLTAJ |
| BAYMAK DUATECH LUNA 3 | E160 | FAN GERİ BESLEME HATASI |
| BAYMAK DUATECH LUNA 3 | E168 | ANA KART FAN ALEV OLUŞUM HATASI |
| BAYMAK DUATECH LUNA 3 | E193 | SİSTEM HAVA YAPMASI |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E10 | DIŞ HAVA SENSÖRÜ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E20 | KALORİFER SENSÖRÜ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E28 | BACA SENSÖRÜ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E50 | SICAK SU SENSÖRÜ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E110 | LİMİT AŞIRI ISI |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E119 | SU BASINÇ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E125 | KURU YANMA SİRKÜLASYON |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E130 | BACA SENSÖRÜ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E133 | ALEV YOKLUĞU İYON |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E151 | DAHİLİ ANA KART |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E156 | DÜŞÜK – YÜKSEK VOLTAJ |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E160 | FAN GERİ BESLEME HATASI |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E168 | ANA KART FAN ALEV OLUŞUM HATASI |
| BAYMAK NOVADENS-NOVADENS EKSTRA- | E193 | SİSTEM HAVA YAPMASI |
| BOSCH CLASSIC/CLASSIC PLUS | B1 | RDW-ZWA |
| BOSCH CALSSIC CONDENSE | B1 | RDC/ZWB/ZWBR/ZBR |
| BOSCH CALSSIC CONDENSE | A7 | d3 |
| BOSCH CALSSIC CONDENSE | A8 | d5 |
| BOSCH CALSSIC CONDENSE | b1 | E9 |
| BOSCH CALSSIC CONDENSE | b2 | / b3 / F1 EA |
| BOSCH CALSSIC CONDENSE | C6 | F0 |
| BOSCH CALSSIC CONDENSE | CC | F7 |
| BOSCH CALSSIC CONDENSE | CE | FA |
| BOSCH CLASS 6000 W | A7 | SICAK SU SENSÖRÜ HATASI |
| BOSCH CLASS 6000 W | C1 | FAN DEVİRİ DÜŞÜK |
| BOSCH CLASS 6000 W | C4 | PROSESTAT |
| BOSCH CLASS 6000 W | C6 | PROSESTAT |
| BOSCH CLASS 6000 W | CE | DÜŞÜK BASINÇ |
| BOSCH CLASS 6000 W | d7 | GAZ VALFİ HATASI |
| BOSCH CLASS 6000 W | E2 | KALORİFER SENSÖRÜ |
| BOSCH CLASS 6000 W | E9 | AŞIRI ISI LİMİT |
| BOSCH CLASS 6000 W | EA | İYONİZASYON |
| BOSCH CLASS 6000 W | F7 | YANLIŞ İYON |
| BOSCH CLASS 6000 W | II | BACA AYARI (PARAMETRE 2.b.d) |
| BOSCH CONDENS 2000 W | A2 | YANMA ODASI SENSÖRÜ KURU YANMA |
| BOSCH CONDENS 2000 W | A7 | SICAK SU SENSÖRÜ |
| BOSCH CONDENS 2000 W | B3 | YOĞUŞMA ESANJÖRÜ YADA YOĞUŞMA GİDERİ |
| BOSCH CONDENS 2000 W | CE | LİMİT AŞIRI ISI POMPA BASINÇ VEYA BY-PASS HATTI |
| BOSCH CONDENS 2000 W | C7 | FAN HIZ KONTROL HATASI |
| BOSCH CONDENS 2000 W | C8 | FAN HIZ KONTROL HATASI |
| BOSCH CONDENS 2000 W | d7 | GAZ VALFİ ARIZASI |
| BOSCH CONDENS 2000 W | E2 | KALORİFER SENSÖRÜ |
| BOSCH CONDENS 2000 W | E9 | LİMİT SENSÖR YADA KART SİGORTASI |
| BOSCH CONDENS 2000 W | EA | İYONİZASYON |
| BOSCH CONDENS 2500 W | A7 | SICAK SU SENSÖRÜ |
| BOSCH CONDENS 2500 W | A8 | BUS İLETİŞİM HATASI |
| BOSCH CONDENS 2500 W | C6 | FAN HATASI |
| BOSCH CONDENS 2500 W | CC | DIŞ HAVA SENSÖRÜ |
| BOSCH CONDENS 2500 W | CE | DÜŞÜK BASINÇ |
| BOSCH CONDENS 2500 W | d3 | KART ÜZERİNDEKİ ”Ɵ” İŞARETLİ KLEMENS BAĞLANTISI |
| BOSCH CONDENS 2500 W | E2 | KALORİFER SENSÖRÜ |
| BOSCH CONDENS 2500 W | E9 | AŞIRI ISI LİMİT |
| BOSCH CONDENS 2500 W | EA | İYONİZASYON |
| BOSCH CONDENS 2500 W | F1 | DAHİLİ HATA |
| BOSCH CONDENS 2500 W | F7 | YANLIŞ İYONİZASYON |
| BOSCH CONDENS 5000 W | H07 | — DÜŞÜK SU BASINCI E9 220 LİMİT SENSÖRÜ ŞASE TEMASI YADA LİMİT ARIZASI |
| BOSCH CONDENS 5000 W | b7 | 257 BRÜLÖR OTOMATİĞİ YADA KİM ARIZASI E9 221 LİMİT SENSÖRÜ BAĞLANTI KOPMASI |
| BOSCH CONDENS 5000 W | C1 | 264 FAN BLOKE HATASI E9 224 AŞIRI ISI LİMİT |
| BOSCH CONDENS 5000 W | C4 | 273 24 SAAT ÇALIŞMA SONRASI DURMA-EMNİYET KONTROLÜ E9 276 KALORİFER GİDİŞ ISISI 95°C’NİN ÜSTÜNDE |
| BOSCH CONDENS 5000 W | C6 | 215 FAN YÜKSEK DEVİR E9 277 LİMİT ISI SENSÖRÜ 95°C’NİN |
| BOSCH CONDENS 5000 W | C6 | 216 FAN DÜŞÜK DEVİR E9 285 KALORİFER DÖNÜŞ ISIS 95°C’NİN ÜSTÜNDE |
| BOSCH CONDENS 5000 W | C7 | 214 FAN GERİ BESLEME EA 227 İYONİZASYON |
| BOSCH CONDENS 5000 W | C7 | 217 FAN DÜZENSİZ DEVİR EA 228 YANLIŞ İYONİZASYON |
| BOSCH CONDENS 5000 W | CE | 207 DÜŞÜK SU BASINCI EA 234 GAZ VALFİ ARIZASI |
| BOSCH CONDENS 5000 W | CE | 266 BASINÇ SENSÖRÜ/ŞALTERİ EA 261 BRÜLÖR OTOMATİĞİ YADA KİM MODULÜ |
| BOSCH CONDENS 5000 W | d1 | 240 KALORİFER DÖNÜŞ SENSÖRÜ KISA DEVRE EH 258 BRÜLÖR OTOMATİĞİ YADA KİM MODULÜ |
| BOSCH CONDENS 5000 W | d1 | 241 KALORİFER DÖNÜŞ SENSÖRÜ KABLOSU KOPMA FO 237…290 BRÜLÖR OTOMATİĞİ YADA KİM MODULÜ |
| BOSCH CONDENS 5000 W | d3 | 232 HARİCİ SENSÖR HATASI FO 278 KALORİFER GİDİŞ VE LİMİT KABLOLARI KISA DEVRE |
| BOSCH CONDENS 5000 W | d4 | 271 SENSÖRLER ARASI ISI FARKI F7 229 İYONİZASYON |
| BOSCH CONDENS 5000 W | d4 | 286 KALORİFER DÖNÜŞ SENSÖRÜ AŞIRI ISI F7 306 YANLIŞ İYONİZASYON |
| BOSCH CONDENS 5000 W | E2 | 222 KALORİFER GİDİŞ SENSÖRÜ KISA DEVRE F7 328 ŞEBEKE GERİLİMİ KISA SÜRELİ KESİNTİ |
| BOSCH CONDENS 5000 W | E2 | 223 KALORİFER GİDİŞ SENSÖRÜ KABLOSU KOPMA Fd 231 ŞEBEKE GERİLİMİ HATASI |
| BOSCH CONDENS 5000 W | E5 | 218 KALORİFER GİDİŞ SENSÖRÜ AŞIRI ISI 9A 235 KİM MODÜLÜ GÜNCEL DEĞİL |
| BOSCH CONDENS 5000 W | E9 | 210 9 VE 10 KONTAKLARI ARASINDAKİ KOPUKLUK 9U 233 BRÜLÖR OTOMATİĞİ YADA KİM MODULÜ |
| BOSCH CONDENS 5000 W | E9 | 219 AŞIRI ISI LİMİT — — — |
| BOSCH EUROSMART | B1 | RDW24 (ZWA 24) |
| BOSCH EUROSMART | Sn/1 | Hz ATEŞLEME -AŞIRI ISI – LİMİT – DAHİLİ HATA -YÜKSEK BASINÇ |
| BOSCH EUROSMART | Sn/4 | Hz KOD ANAHTARI |
| BOSCH EUROSMART | Sn/8 | Hz TEST KONUMU |
| BOSCH EUROMAXX-CERASMART | A3 | CA |
| BOSCH EUROMAXX-CERASMART | A4 | CC |
| BOSCH EUROMAXX-CERASMART | A7 | d3 |
| BOSCH EUROMAXX-CERASMART | A8 | E2 |
| BOSCH EUROMAXX-CERASMART | b1 | FO |
| BOSCH EUROMAXX-CERASMART | C1 | F7 |
| BOSCH EUROMAXX-CERASMART | C4 | FA |
| BOSCH EUROMAXX-CERASMART | C6 | Fd |
| BOSCH EXCLUSIVE/COMFORT | B1 | RDW-ZWC (MFA-MFK) |
| BOSCH EXCLUSIVE/COMFORT | A3 | d4 |
| BOSCH EXCLUSIVE/COMFORT | A4 | d7 |
| BOSCH EXCLUSIVE/COMFORT | A6 | EO-FO |
| BOSCH EXCLUSIVE/COMFORT | A8 | E2 |
| BOSCH EXCLUSIVE/COMFORT | B1 | EA |
| BOSCH EXCLUSIVE/COMFORT | C1 | F7 |
| BOSCH EXCLUSIVE/COMFORT | C4 | FA |
| BOSCH EXCLUSIVE/COMFORT | C6 | Fd |
| BOSCH EUROSMİLE | B1 | RDW 23 (ZW 23) |
| BOSCH EUROSMİLE | 90 | ° |
| BUDERUS GB012 | II | BACA AYARI (PARAMETRE 2.b.d) |
| BUDERUS GB012 | B3 | YOĞUŞMA GİDERİ TIKALI YADA DIŞ KAÇAK |
| BUDERUS GB012 | CL | SICAK SU SENSÖRÜ |
| BUDERUS GB012 | d7 | MODÜLASYON BOBİNİ |
| BUDERUS GB032 | A7 | SICAK SU SENSÖRÜ |
| BUDERUS GB032 | A8 | EKO PANEL İLETİŞİMİ |
| BUDERUS GB032 | A9 | SICAK SU SENSÖRÜ |
| BUDERUS GB032 | B1 | KOD ANAHTARI |
| BUDERUS GB032 | C1 | FAN DEVİRİ DÜŞÜK |
| BUDERUS GB032 | CC | DIŞ HAVA SENSÖRÜ |
| BUDERUS GB032 | d3 | ST8’DEKİ 161 KÖPRÜSÜ |
| BUDERUS GB032 | E2 | KALORİFER SENSÖRÜ |
| BUDERUS GB032 | E8 | OTO DOLDURMA AKTİF |
| BUDERUS GB032 | E9 | AŞIRI ISI LİMİT |
| BUDERUS GB032 | EA | İYONİZASYON |
| BUDERUS GB032 | F7 | YANLIŞ İYONİZASYON |
| BUDERUS GB042 | CE | HARİCİ DENGE KABI SENSÖR HATASI |
| BUDERUS GB042 | CL | SICAK SU SENSÖRÜ HATASI |
| BUDERUS GB042 | EP | RESET KİTLEMESİ |
| BUDERUS GB062 | CC | DIŞ HAVA SENSÖRÜ |
| BUDERUS GB062 | CL | SICAK SU SENSÖRÜ |
| BUDERUS GB062 | EP | RESET KİTLEMESİ |
| BUDERUS GB072 | OC | TEKRAR DEVRE ALMA MODU 6A İYONİZASYON |
| BUDERUS GB 112 – 122 | 2 | SU AKIMI H GERİLİM HATASI |
| BUDERUS GB 112 – 122 | 3 | HAVA DEBİSİ 9 SİSTEM HATASI |
| BUDERUS GB 112 – 122 | 4 | SICAKLIKLAR C KIM DE YANLIŞ BAĞLANTI |
| BUDERUS | OC | 283 HAZIRLIK EVRESİ 7L 261 UBA 3 ARIZALI |
| BUDERUS GB 172 | 2 | Y 281 ISITMA POMPASI ISI ÜRETEMİYOR 9A 235 KOD ANAHTARI HATASI |
| BUDERUS UO52-UO54 | A7 | d3 |
| BUDERUS UO52-UO54 | A8 | d5 |
| BUDERUS UO52-UO54 | b1 | E9 |
| BUDERUS UO52-UO54 | b2 | / b3 / F1 EA |
| BUDERUS UO52-UO54 | C6 | F0 |
| BUDERUS UO52-UO54 | CC | F7 |
| BUDERUS UO52-UO54 | CE | FA |
| BUDERUS UO62 | ST8 | DEKİ KÖPRÜ |
| BUDERUS UO72 | C7 | FAN BLOKAJ |
| BUDERUS UO72 | CL | SICAK SU SENSÖR HATASI |
| BUDERUS UO72 | d7 | GAZ VALFİ HATASI |
| BUDERUS | 2 | SU AKIMI H GERİLİM HATASI |
| BUDERUS | 3 | HAVA DEBİSİ 9 SİSTEM HATASI |
| BUDERUS | 4 | SICAKLIKLAR C KIM DE YANLIŞ BAĞLANTI |
| DE DİETRİCH | B00 | YAPILANDIRMA HATASI M20 KAZAN SÜPÜRME MODU AKTİF L35 FAN DEVİR HATASI |
| DE DİETRİCH | B01 | LİMİT CİHAZ BEKLEMEDE KALIYOR L36 İYONİZASYON |
| DE DİETRİCH | B02 | LİMİT M23 DIŞ HAVA SENSÖRÜ L37 SU ELEKTRONİK KART İLETİŞİM HATASI |
| DE DİETRİCH | B07 | SENSÖRLER ARASI AŞIRI ISI FARKI M30 MOD BUS KART İLETİŞİM ARIZASI L38 PCU VE SCU BAĞLANTI HATASI |
| DE DİETRİCH | B08 | ELEKTRONİK KART AÇIK M31 MOD BUS YANLIŞ YAPILANDIRMA L39 BL GİRİŞİ AÇIK |
| DE DİETRİCH | B09 | SERVİS ARIZASI DURDURMA AKTİF L40 SENSÖR TEST HATASI |
| DE DİETRİCH | B10 | TERMİNAL BLOĞUNDAKİ BL GİRİŞİ PCU |
| DE DİETRİCH | B11 | ELEKTRONİK KART AÇIK LOO PSU KARTI BAĞLI DEĞİL L250 DÜŞÜK SU BASINCI |
| DE DİETRİCH | B13 | İLETİŞİM HATASI LO1 GÜVENLİK AYARI YANLIŞ L251 YÜKSEK SU BASINCI |
| DE DİETRİCH | B14 | DÜŞÜK SU BASINCI LO2 KALORİFER SENSÖRÜ DO3 B,C PROB HATASI |
| DE DİETRİCH | B15 | DÜŞÜK GAZ BASINCI LO4 KALORİFER SENSÖRÜ DO5 DIŞ HAVA SENSÖRÜ HATASI |
| DE DİETRİCH | B16 | SU(ANAHTAR) MODÜLÜ HATASI LO5 KAZAN SICAKLIĞI ÇOK DÜŞÜK DO7 SİSTEM PROBU HATASI |
| DE DİETRİCH | B17 | PSU (ANA KART) HATASI LO6 KAZAN SICAKLIĞI ÇOK YÜKSEK DO9 SICAK SU SENSÖRÜ |
| DE DİETRİCH | B18 | PSU (ANA KART) HATASI LO7 KALORİFER DÖNÜŞ SENSÖRÜ D13 ODA SENSÖRÜ HATASI |
| DE DİETRİCH | B19 | KAZAN YAPILANDIRILMAMIŞ LO8 KALORİFER DÖNÜŞ SENSÖRÜ D14 SCU KART VE KAZAN KARTI İLETİŞİM HATASI |
| DE DİETRİCH | B21 | ANAHTAR VE ANA KART YAPILANDIRLMAMIŞLO9 DÖNÜŞ SICAKLIĞI ÇOK DÜŞÜK D 15 SENSÖR HATASI |
| DE DİETRİCH | B22 | İYONİZASYON L10 DÖNÜŞ SICAKLIĞI ÇOK YÜKSEK D16 SENSÖR HATASI |
| DE DİETRİCH | B25 | DAHİLİ HATA SU KİM HATASI L11 NTC’LER ARASI ISI FARKI D17 SENSÖR HATASI |
| DE DİETRİCH | B26 | BOYLER SENSÖRÜ HATASI L12 NTC’LER ARASI ISI FARKI D27 PCU VE SCU BAĞLANTI HATASI |
| DE DİETRİCH | 5 | DENEMEDE SİSTEMİN DEVREYE |
| DE DİETRİCH | B27 | PLAKA BAĞLANTISI VEYA SENSÖR L14 LİMİT D32 GİREMEMESİ |
| DE DİETRİCH | M04 | BAKIM HATASI L15 5 BAŞARISIZ BRÜLÖR HATASI D37 TİTAN ACTİVE SİSTEM HATASI |
| DE DİETRİCH | M05 | A,B,C KONUMU REVİZYON ARAMASI L16 İYON PARAZİTLENMESİ D38 TİTAN ACTİVE SİSTEM HATASI |
| DE DİETRİCH | M06 | A,B,C KONUMU REVİZYON ARAMASI L17 SU ELEKTRİK KART HATASI D99 UCS PCU SİSTEMİNİ TANIMIYOR |
| DE DİETRİCH | M07 | A,B,C KONUMU REVİZYON ARAMASI L34 FAN DEVİR HATASI |
| DEMİR DÖKÜM | 30 | C – F3 KALORİFER SENSÖRÜ |
| DEMİR DÖKÜM | 40 | C – F2 SICAK SU SENSÖRÜ |
| DEMİR DÖKÜM | 50 | C – F6 DIŞ HAVA SENSÖRÜ |
| DEMİR DÖKÜM | 60 | C – F0 SU BASINCI |
| DEMİR DÖKÜM | 70 | C – F5 FAN PRESOSTAT |
| DEMİR DÖKÜM | 80 | C – F1 LİMİT |
| DEMİR DÖKÜM | 90 | C – F4 ALEV YOKLUĞU |
| DEMİR DÖKÜM | OC | DIŞ HAVA SENSÖRÜ AKTİF |
| DEMİR DÖKÜM | CC | DIŞ HAVA SENSÖRÜ İPTAL |
| DEMİR DÖKÜM ATRON | F01 | AŞIRI ISI |
| DEMİR DÖKÜM ATRON | F02 | SICAK SU NTC |
| DEMİR DÖKÜM ATRON | F03 | KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM ATRON | F04 | İYONİZASYON |
| DEMİR DÖKÜM ATRON | F05 | PROSESTAT KONTAKLARI KAPANMIYOR |
| DEMİR DÖKÜM ATRON | F06 | KALORİFER DÖNÜŞ NTC |
| DEMİR DÖKÜM ATRON | F07 | GAZ VALFİ ARIZASI |
| DEMİR DÖKÜM ATRON | F08 | AŞIRI ISI VE KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM ATRON | F09 | PROSESTAT KONTAKLARI AÇIK KALMIŞ |
| DEMİR DÖKÜM ATRON | F10 | SU BASIN HATASI |
| DEMİR DÖKÜM ATRON | F11 | SİRKÜLASYON HATASI |
| DEMİR DÖKÜM ATRON | F12 | DÜŞÜK VOLTAJ HATASI |
| DEMİR DÖKÜM ATRON | F13 | KALORİFER NTC’LERİ HATASI |
| DEMİR DÖKÜM ATRON | F88 | NTC SENSÖR |
| DEMİR DÖKÜM İSOFAST | 1 | İYONİZASYON 23 SICAKLIĞIN HIZLI YÜKSELMESİ |
| DEMİR DÖKÜM İSOFAST | 2 | HAVA AKIŞ HATASI 33 TA1 HABERLEŞME HATASI |
| DEMİR DÖKÜM İSOFAST | 3 | HAVA AKIŞ HATASI 34 DIŞ HAVA SENSÖRÜ HATASI |
| DEMİR DÖKÜM İSOFAST | 4 | İYONİZASYON 35 HABERLEŞME ROLESİ HATASI |
| DEMİR DÖKÜM İSOFAST | 5 | AŞIRI ISI LİMİT 36 TA2 HABERLEŞME HATASI |
| DEMİR DÖKÜM İSOFAST | 6 | KALORİFER NTC 38 TA1 HABERLEŞME HATASI |
| DEMİR DÖKÜM İSOFAST | 7 | SICAK SU NTC 39 DIŞ HAVA SENSÖRÜ HATASI |
| DEMİR DÖKÜM İSOFAST | 8 | BOYLER SENSÖRÜ 40 HABERLEŞME ROLESİ HATASI |
| DEMİR DÖKÜM İSOFAST | 9 | BASINÇ HATASI 41 TA2 HABERLEŞME HATASI |
| DEMİR DÖKÜM İSOFAST | 10 | KALORİFER DÖNÜŞ NTC 65 YERDEN ISITMA SENSÖRÜ |
| DEMİR DÖKÜM İSOFAST | 11 | ANA KART HATASI 66 KALORİFER DÖNÜŞ SENSÖRÜ |
| DEMİR DÖKÜM İSOFAST | 12 | EKRAN KARTI İLETİŞİM HATASI 67 BOYLER LİMİT HATASI |
| DEMİR DÖKÜM İSOFAST | 13 | ANA KART HATASI 68 KALORİFER DÖNÜŞ SENSÖRÜ |
| DEMİR DÖKÜM İSOFAST | 14 | LİMİT 69 YERDEN ISITMA AŞIRI ISI |
| DEMİR DÖKÜM İSOFAST | 15 | GAZ VALFİ STEP MOTOR HATASI 70 3 YOLLU VANA HATASI |
| DEMİR DÖKÜM İSOFAST | 16 | İYONİZASYON 71 3 YOLLU VANA HATASI |
| DEMİR DÖKÜM İSOFAST | 17 | DÜŞÜK VOLTAJ HATASI 72 ECOPANEL HATASI |
| DEMİR DÖKÜM İSOFAST | 18 | EKRAN KARTI İLETİŞİM HATASI 73 YERDEN ISITMA 51 C DEN YÜKSEK |
| DEMİR DÖKÜM İSOFAST | 19 | KALORİFER NTC 75 YERDEN ISITMA SİRKÜLASYON HATASI |
| DEMİR DÖKÜM İSOFAST | 20 | EKRAN İLE ANA KART UYUMSUZ 81 GAZ VALFİ STEP MOTOR HATASI |
| DEMİR DÖKÜM İSOFAST | 21 | SİRKÜLASYON-POMPA HATASI 82 ANA KART HATASI |
| DEMİR DÖKÜM KALİSTO | F1 | AŞIRI ISI |
| DEMİR DÖKÜM KALİSTO | F2 | SICAK SU NTC |
| DEMİR DÖKÜM KALİSTO | F3 | KALORİFER NTC |
| DEMİR DÖKÜM KALİSTO | F4 | İYANİZASYON |
| DEMİR DÖKÜM KALİSTO | F5 | FAN PROSESTAT |
| DEMİR DÖKÜM KALİSTO | F6 | DIŞ HAVA SENSÖRÜ |
| DEMİR DÖKÜM KALİSTO | F7 | SU BASINÇ |
| DEMİR DÖKÜM KALİSTO | 88 | FAN PROSESTAT |
| DEMİR DÖKÜM KALİSTO | 88 | BESLEME HATTI PROBLEMİ |
| DEMİR DÖKÜM KALİSTO | OC | DIŞ HAVA SENSÖRÜ AKTİF |
| DEMİR DÖKÜM KALİSTO | CC | DIŞ HAVA SENSÖRÜ İPTAL |
| DEMİR DÖKÜM | F1 | BRÜLÖR YANMIYOR 10 SN. SONRA KAPATIYOR ATEŞLEM TRAFOSU – GAZ VALFİ |
| DEMİR DÖKÜM | F2 | FAN PROSESTAT |
| DEMİR DÖKÜM | F3 | FAN PROSESTAT |
| DEMİR DÖKÜM | F4 | BRÜLÖR YANMIYOR 10 SN. SONRA KAPATIYOR ATEŞLEM TRAFOSU – GAZ VALFİ |
| DEMİR DÖKÜM | F4 | BRÜLÖR YANIYOR ALEV GÖRMEME İYONİZASYON |
| DEMİR DÖKÜM | F9 | KOMBİ ÇALIŞMADAN DİREK YANARSA BASINÇ SİVİCİ-NTC-LİMİT |
| DEMİR DÖKÜM | F9 | BRÜLÖR YANMIYOR 10 SN. SONRA KAPATIYOR STEP MOTOR |
| DEMİR DÖKÜM | F9 | MODÜLASYON YAPMAMA STEP MOTOR |
| DEMİR DÖKÜM | F9 | BRÜLÖR YANMIYOR HEMEN F9’A GEÇİYOR ÇIKMIYOR ANA KART-KABLO GRUBU |
| DEMİR DÖKÜM NEPTO | F01 | AŞIRI ISI |
| DEMİR DÖKÜM NEPTO | F02 | SICAK SU NTC |
| DEMİR DÖKÜM NEPTO | F03 | KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM NEPTO | F04 | İYONİZASYON |
| DEMİR DÖKÜM NEPTO | F05 | PROSESTAT KONTAKLARI KAPANMIYOR |
| DEMİR DÖKÜM NEPTO | F06 | KALORİFER DÖNÜŞ NTC |
| DEMİR DÖKÜM NEPTO | F07 | GAZ VALFİ ARIZASI |
| DEMİR DÖKÜM NEPTO | F08 | AŞIRI ISI VE KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM NEPTO | F09 | PROSESTAT KONTAKLARI AÇIK KALMIŞ |
| DEMİR DÖKÜM NEPTO | F10 | SU BASIN HATASI |
| DEMİR DÖKÜM NEPTO | F11 | SİRKÜLASYON HATASI |
| DEMİR DÖKÜM NEPTO | F12 | DÜŞÜK VOLTAJ HATASI |
| DEMİR DÖKÜM NEPTO | F13 | KALORİFER NTC’LERİ HATASI |
| DEMİR DÖKÜM NEPTO | F88 | NTC SENSÖR |
| DEMİR DÖKÜM NEVA | F01 | AŞIRI ISI |
| DEMİR DÖKÜM NEVA | F02 | SICAK SU NTC |
| DEMİR DÖKÜM NEVA | F03 | KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM NEVA | F04 | İYONİZASYON |
| DEMİR DÖKÜM NEVA | F05 | PROSESTAT KONTAKLARI KAPANMIYOR |
| DEMİR DÖKÜM NEVA | F06 | KALORİFER DÖNÜŞ NTC |
| DEMİR DÖKÜM NEVA | F07 | GAZ VALFİ ARIZASI |
| DEMİR DÖKÜM NEVA | F08 | AŞIRI ISI VE KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM NEVA | F09 | PROSESTAT KONTAKLARI AÇIK KALMIŞ |
| DEMİR DÖKÜM NEVA | F10 | SU BASIN HATASI |
| DEMİR DÖKÜM NEVA | F11 | SİRKÜLASYON HATASI |
| DEMİR DÖKÜM NEVA | F12 | DÜŞÜK VOLTAJ HATASI |
| DEMİR DÖKÜM NEVA | F13 | KALORİFER NTC’LERİ HATASI |
| DEMİR DÖKÜM NEVA | F88 | NTC SENSÖR |
| DEMİR DÖKÜM NİTRON | F1 | AŞIRI ISI |
| DEMİR DÖKÜM NİTRON | F2 | SICAK SU NTC |
| DEMİR DÖKÜM NİTRON | F3 | KALORİFER NTC |
| DEMİR DÖKÜM NİTRON | F4 | İYANİZASYON |
| DEMİR DÖKÜM NİTRON | F5 | FAN PROSESTAT |
| DEMİR DÖKÜM NİTRON | F6 | DIŞ HAVA SENSÖRÜ |
| DEMİR DÖKÜM NİTRON | F7 | SU BASINÇ |
| DEMİR DÖKÜM NİTRON | 88 | FAN PROSESTAT |
| DEMİR DÖKÜM NİTRON | 88 | BESLEME HATTI PROBLEMİ |
| DEMİR DÖKÜM NİTRON | OC | DIŞ HAVA SENSÖRÜ AKTİF |
| DEMİR DÖKÜM NİTRON | CC | DIŞ HAVA SENSÖRÜ İPTAL |
| DEMİR DÖKÜM NİTRON PLUS | F01 | AŞIRI ISI |
| DEMİR DÖKÜM NİTRON PLUS | F02 | SICAK SU NTC |
| DEMİR DÖKÜM NİTRON PLUS | F03 | KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM NİTRON PLUS | F04 | İYONİZASYON |
| DEMİR DÖKÜM NİTRON PLUS | F05 | PROSESTAT KONTAKLARI KAPANMIYOR |
| DEMİR DÖKÜM NİTRON PLUS | F06 | KALORİFER DÖNÜŞ NTC |
| DEMİR DÖKÜM NİTRON PLUS | F07 | GAZ VALFİ ARIZASI |
| DEMİR DÖKÜM NİTRON PLUS | F08 | AŞIRI ISI VE KALORİFER GİDİŞ NTC |
| DEMİR DÖKÜM NİTRON PLUS | F09 | PROSESTAT KONTAKLARI AÇIK KALMIŞ |
| DEMİR DÖKÜM NİTRON PLUS | F10 | SU BASIN HATASI |
| DEMİR DÖKÜM NİTRON PLUS | F11 | SİRKÜLASYON HATASI |
| DEMİR DÖKÜM NİTRON PLUS | F12 | DÜŞÜK VOLTAJ HATASI |
| DEMİR DÖKÜM NİTRON PLUS | F13 | KALORİFER NTC’LERİ HATASI |
| DEMİR DÖKÜM NİTRON PLUS | F14 | İYONİZASYON |
| DEMİR DÖKÜM NİTRON PLUS | F15 | İYONİZASYON |
| DEMİR DÖKÜM | F0 | DÜŞÜK SU BASINCI |
| DEMİR DÖKÜM | F1 | AŞIRI ISI LİMİT |
| DEMİR DÖKÜM | F2 | KALORİFER NTC |
| DEMİR DÖKÜM | F3 | SICAK SU NTC |
| DEMİR DÖKÜM | F4 | İYANİZASYON |
| DEMİR DÖKÜM | F5 | HAVA AKIŞI PROBLEMİ |
| DEMİR DÖKÜM | F6 | DIŞ HAVA SENSÖRÜ HATASI |
| DEMİR DÖKÜM | F7 | FAN GERİ BESLEME |
| DEMİR DÖKÜM | F8 | FAN DEVİR HATASI |
| DEMİR DÖKÜM | F9 | FAN SÜREKLİ SÜPÜRME HATASI |
| DEMİR DÖKÜM | OC | DIŞ HAVA SENSÖRÜ AKTİF |
| DEMİR DÖKÜM | CC | DIŞ HAVA SENSÖRÜ KAPALI |
| DEMİR DÖKÜM | F1 | AŞIRI ISI LİMİT |
| DEMİR DÖKÜM | F2 | NTC SENSÖR |
| DEMİR DÖKÜM | F4 | İYONİZASYON |
| DEMİR DÖKÜM | F5 | FAN PROSESTAT |
| E.C.A. CALORA PREMİX | E01 | İYON ALEV YOKLUĞU F34 DÜŞÜK VOLTAJ HATASI |
| E.C.A. CALORA PREMİX | E02 | İYON ALEV YOKLUĞU F35 KALORİFER SENSÖR |
| E.C.A. CALORA PREMİX | E03 | AŞIRI ISI LİMİT F37 SU BASINÇ |
| E.C.A. CALORA PREMİX | E05 | FAN GERİ BESLEME F39 DIŞ HAVA SENSÖRÜ |
| E.C.A. CALORA PREMİX | E08 | ATEŞLEME HATASI F40 YÜKSEK SU BASINÇ |
| E.C.A. CALORA PREMİX | E09 | GAZ VALFİ F41/42/43 |
| E.C.A. CALORA PREMİX | E12 | EPROM F50 BOYLER SENSÖRÜ |
| E.C.A. CALORA PREMİX | E21 | DAHİLİ KART HATASI F51 PT1000 BOYLER SENSÖRÜ |
| E.C.A. CALORA PREMİX | E33 | DÖNÜŞ SENSÖR F52 SICAK SU SENSÖRÜ |
| E.C.A. CALORA PREMİX | E35 | ÇIKIŞ SENSÖR F53 TERMAL SİGORTA |
| E.C.A. CALORA PREMİX | F13 | RESET KİTLEMESİ F81 SENSÖRLER ARASI ISI FARKI |
| E.C.A CONFEO | 40 | 50 60 70 80 ARIZA AÇIKLAMASI |
| E.C.A CONFEO PLUS | 1 | AŞIRI ISI LİMİT 31 GÜVENLİK PARAMETRE HATASI |
| E.C.A CONFEO PLUS | 4 | İYONİZASYON 32 VOLTAJ HATASI |
| E.C.A CONFEO PLUS | 5 | ATEŞLEMEME 34 BCC HATASI |
| E.C.A CONFEO PLUS | 6 | AŞIRI ISI LİMİT 35 BCC TAKILMAMIŞ |
| E.C.A CONFEO PLUS | 7 | BACA GAZI SENSÖRÜ 36 BCC HATASI |
| E.C.A CONFEO PLUS | 10 | AŞIRI ISI LİMİT 37 BCC HATASI |
| E.C.A CONFEO PLUS | 11 | ALEV KOPARMA 38 BCC HATASI |
| E.C.A CONFEO PLUS | 12 | KALORİFER SENSÖRÜ 39 HATALI BCC MONTAJI |
| E.C.A CONFEO PLUS | 13 | BACA GAZI SENSÖRÜ 40 DÜŞÜK SU BASINCI |
| E.C.A CONFEO PLUS | 14 | SICAK SU NTC(PREMİX’TE BOYLER NTC) 42 YÜKSEK SU BASINCI |
| E.C.A CONFEO PLUS | 16 | KALORİFER DÖNÜŞ SENSÖRÜ 50 BCC AKTİVASYON |
| E.C.A CONFEO PLUS | 20 | MODÜLASYON HATASI 52 BCC KOPYALAMA |
| E.C.A CONFEO PLUS | 24 | FAN DEVİR HATASI 99 DAHİLİ HATA |
| E.C.A CONFEO PLUS | 30 | PARAMETRE HATASI Oп COMFORT KİTLEMESİ |
| E.C.A EUROSTAR | A3 | CA |
| E.C.A EUROSTAR | A4 | CC |
| E.C.A EUROSTAR | A7 | d3 |
| E.C.A EUROSTAR | A8 | E2 |
| E.C.A EUROSTAR | b1 | FO |
| E.C.A EUROSTAR | C1 | F7 |
| E.C.A EUROSTAR | C4 | FA |
| E.C.A EUROSTAR | C6 | Fd |
| E.C.A FORTİUS | a1 | DÜŞÜK VOLTAJ t1 AŞIRI ISI LİMİT |
| E.C.A FORTİUS | d1 | GAZ VALFİ ALEV KOPMASI t2 BACA GAZI SENSÖRÜ |
| E.C.A FORTİUS | E1 | İYANİZASYON t3 KALORİFER SENSÖRÜ |
| E.C.A FORTİUS | E2 | YANLIŞ İYANİZASYON t5 SICAK SU SENSÖRÜ |
| E.C.A FORTİUS | E3 | AŞIRI ISI LİMİT t6 BACA GAZI SENSÖRÜ |
| E.C.A FORTİUS | E4 | HAVA PROSESTAT – FAN t7 DIŞ HAVA SENSÖRÜ |
| E.C.A FORTİUS | E5 | HAVA PROSESTAT – FAN y1 GAZ VALFİ ARIZASI |
| E.C.A FORTİUS | p1 | SU BASINCI c1 ANA KART – EKRAN KARTI – VOLTAJ |
| E.C.A KRONOS | F1 | AŞIRI ISI LİMİT F9 GAZ VALFİ HATASI |
| E.C.A KRONOS | F2 | SICAK SU SENSÖRÜ F10 BACA GAZI SENSÖRÜ |
| E.C.A KRONOS | F3 | KALORİFER SENSÖRÜ F11 SİFON TIKANMASI |
| E.C.A KRONOS | F4 | İYONİZASYON HATASI F12 FAN DEVİR HATSI |
| E.C.A KRONOS | F5 | FAN PROSESTAT HATASI F13 MERKEZİ ISITMA SENSÖRÜ |
| E.C.A NOVASTAR | 4 | SN. 1 DEFA AŞIRI ISI LİMİT |
| E.C.A NOVASTAR | 2 | SN. 1 DEFA İYONİZASYON |
| E.C.A NOVASTAR | 2 | SN. 1 DEFA AŞIRI ISI LİMİT |
| E.C.A NOVASTAR | 1 | SN. 3 YAN SÖN |
| E.C.A NOVASTAR | 1 | SN. 2 YAN SÖN |
| E.C.A NOVASTAR | 1 | SN. 1 YAN SÖN |
| E.C.A PROTEUS PREMİX | E01 | İYON ALEV YOKLUĞU F34 DÜŞÜK VOLTAJ HATASI |
| E.C.A PROTEUS PREMİX | E02 | İYON ALEV YOKLUĞU F35 KALORİFER SENSÖR |
| E.C.A PROTEUS PREMİX | E03 | AŞIRI ISI LİMİT F37 SU BASINÇ |
| E.C.A PROTEUS PREMİX | E05 | FAN GERİ BESLEME F39 DIŞ HAVA SENSÖRÜ |
| E.C.A PROTEUS PREMİX | E08 | ATEŞLEME HATASI F40 YÜKSEK SU BASINÇ |
| E.C.A PROTEUS PREMİX | E09 | GAZ VALFİ F41/42/43 |
| E.C.A PROTEUS PREMİX | E12 | EPROM F50 BOYLER SENSÖRÜ |
| E.C.A PROTEUS PREMİX | E21 | DAHİLİ KART HATASI F51 PT1000 BOYLER SENSÖRÜ |
| E.C.A PROTEUS PREMİX | E33 | DÖNÜŞ SENSÖR F52 SICAK SU SENSÖRÜ |
| E.C.A PROTEUS PREMİX | E35 | ÇIKIŞ SENSÖR F53 TERMAL SİGORTA |
| E.C.A PROTEUS PREMİX | F13 | RESET KİTLEMESİ F81 SENSÖRLER ARASI ISI FARKI |
| E.C.A. ŞOFBEN | AP | FAN PROSESTAT |
| E.C.A. ŞOFBEN | Lt | AŞIRI ISI LİMİT |
| E.C.A. ŞOFBEN | Bu | VOLTAJ HATASI |
| E.C.A. ŞOFBEN | Pb | SENSÖR HATASI |
| E.C.A. ŞOFBEN | No | MODÜLASYON HATASI |
| E.C.A. ŞOFBEN | Ht | AŞIRI ISI LİMİT |
| E.C.A. ŞOFBEN | FL | YANLIŞ İYON HATASI |
| E.C.A. ŞOFBEN | FS | YANLIŞ İYON HATASI |
| E.C.A. ŞOFBEN | FE | YANLIŞ İYON HATASI |
| FERROLİ DOMİCOMPACT | F1 | İYONİZASYON |
| FERROLİ DOMİCOMPACT | F3 | AŞIRI ISI LİMİT |
| FERROLİ DOMİCOMPACT | F2 | YANLIŞ İYONİZASYON |
| FERROLİ DOMİCOMPACT | F5 | FAN PROSESTAT BACA SENSÖRÜ |
| FERROLİ DOMİCOMPACT | F37 | SU BASIN HATASI |
| FERROLİ DOMİCOMPACT | F7 | KALORİFER NTC |
| FERROLİ DOMİCOMPACT | F9 | SICAK SU NTC |
| FERROLİ | A01 | ATEŞLEME HATASI F35 VOLTAJ HATASI |
| FERROLİ | A02 | YANLIŞ İYONİZASYON F37 SU BASINÇ HATASI |
| FERROLİ | A03 | AŞIRI ISI LİMİT F39 DIŞ HAVA SENSÖRÜ |
| FERROLİ | A06 | DÜŞÜK MODÜLASYON F40 SU BASINÇ HATASI |
| FERROLİ | A15 | 5 KEZ F05 VERME HATASI F41 ÇIKIŞ SENSÖRÜ |
| FERROLİ | F05 | FAN PROSESTAT HATASI F42 SICAK SU SENSÖRÜ |
| FERROLİ | F10 | ÇIKIŞ SENSÖRÜ HATASI F43 SİRKÜLASYON HATASI |
| FERROLİ | F11 | SICAK SU SENSÖRÜ F47 SU BASINÇ HATASI |
| FERROLİ | F14 | ÇIKIŞ SENSÖRÜ HATASI F50 MODÜLASYON HATASI |
| FERROLİ | F34 | VOLTAJ HATASI |
| FERROLİ | 1 | A01 İYONİZASYON 24 A24 24 SAATE 3 DOLDURMA İŞLEMİ |
| FERROLİ | 2 | A02 İYONİZASYON 34 F34 AĞ GERİLİM HATASI |
| FERROLİ | 3 | A03 AŞIRI ISI LİMİT 35 F35 AĞ FREKANS HATASI |
| FERROLİ | 4 | A04 GÜNDE 3 KEZ F07 HATASI 36 F36 SU BASINÇ HATASI |
| FERROLİ | 5 | A05 F15 HATASI 1SAAT SÜRDÜ 37 F37 DIŞ HAVA SENSSÖRÜ HATASI |
| FERROLİ | 6 | A06 İYONİZASYON 38 F38 YÜKSEK SU BASINCI |
| FERROLİ | 7 | F07 BACA ISISI YÜKSEK 39 F39 SENSÖR BLOKAJ |
| FERROLİ | 8 | F08 AŞIRI ISI LİMİT 40 F40 HIZLI ISI YÜKSELMESİ |
| FERROLİ | 9 | F09 AŞIRI ISI LİMİT 41 A42 BASINÇ SİVİÇ KORUMA |
| FERROLİ | 10 | F10 KALORİFER SENSÖR 47 A47 AŞIRI ISI LİMİT |
| FERROLİ | 11 | F11 KALORİFER SENSÖR 50 F50 ANA KART ARIZASI |
| FERROLİ | 12 | F12 SICAK SU SENSÖR 61 A61 GAZ VALFİ İLETİŞİM |
| FERROLİ | 13 | F13 BACA SENSÖRÜ 62 A62 ANA KART ARIZASI |
| FERROLİ | 14 | F14 NTC EMNİYET SENSÖRÜ 63 A63 KUMANDA İLE 5 DEFA RESETLEME |
| FERROLİ | 15 | F15 FAN GERİ BESLEME 64 A64 ANA KART ARIZASI |
| FERROLİ ECONCEPT | F1 | ALEV YOKLUĞU F32 SICAK SU SENSÖRÜ |
| FERROLİ ECONCEPT | F3 | AŞIRI ISI LİMİT F33 SICAK SU SENSÖRÜ |
| FERROLİ ECONCEPT | F4 | HAVA PROSESTAT F34 VOLTAJ HATASI |
| FERROLİ ECONCEPT | F5 | HAVA PROSESTAT F35 VOLTAJ HATASI |
| FERROLİ ECONCEPT | F6 | HAVA PROSESTAT F36 ANA KART HATASI |
| FERROLİ ECONCEPT | F8 | ATEŞLEME HATASI F37 SU BASINÇ HATASI |
| FERROLİ ECONCEPT | F9 | GAZ VALFİ İLETİŞİM HATASI F39 DIŞ HAVA SENSÖRÜ |
| FERROLİ ECONCEPT | F10 | İŞLEMCİ HATASI F40 YÜKSEK SU ASINCI |
| FERROLİ ECONCEPT | F22 | İŞLEMCİ HATASI F41 SU BASINÇ HATASI |
| FERROLİ ECONCEPT | F23 | SU BASINÇ HATASI F43 DÖNÜŞ SENSÖRÜ |
| FERROLİ ECONCEPT | F24 | DÜŞÜK SU BASINÇ HATASI F44 DÖNÜŞ SENSÖRÜ |
| FERROLİ ECONCEPT | F25 | YAZILIM HATASI F45 DUMAN SENSÖRÜ |
| FERROLİ ECONCEPT | F30 | KALORİFER SENSÖRÜ HATASI F46 DUMAN SENSÖRÜ |
| FERROLİ ECONCEPT | F31 | KALORİFER SENSÖRÜ HATASI |
| FERROLİ NEW ELİTE | F1 | ALEV YOKLUĞU F25 YAZILIM HATASI |
| FERROLİ NEW ELİTE | F3 | AŞIRI ISI LİMİT F30 KALORİFER SENSÖRÜ HATASI |
| FERROLİ NEW ELİTE | F4 | HAVA PROSESTAT F31 KALORİFER SENSÖRÜ HATASI |
| FERROLİ NEW ELİTE | F5 | HAVA PROSESTAT F32 SICAK SU SENSÖRÜ |
| FERROLİ NEW ELİTE | F6 | HAVA PROSESTAT F33 SICAK SU SENSÖRÜ |
| FERROLİ NEW ELİTE | F8 | ATEŞLEME HATASI F34 VOLTAJ HATASI |
| FERROLİ NEW ELİTE | F9 | GAZ VALFİ İLETİŞİM HATASI F35 VOLTAJ HATASI |
| FERROLİ NEW ELİTE | F10 | İŞLEMCİ HATASI F36 ANA KART HATASI |
| FERROLİ NEW ELİTE | F22 | İŞLEMCİ HATASI F37 SU BASINÇ HATASI |
| FERROLİ NEW ELİTE | F23 | SU BASINÇ HATASI F39 DIŞ HAVA SENSÖRÜ |
| FERROLİ NEW ELİTE | F24 | DÜŞÜK SU BASINÇ HATASI F40 YÜKSEK SU ASINCI |
| MAKTEK EPSİLON | F1 | İYONİZASYON |
| MAKTEK EPSİLON | F2 | AŞIRI ISI LİMİT |
| MAKTEK EPSİLON | F4 | SU BASINÇ HATASI |
| MAKTEK EPSİLON | F5 | KALORİFER SENSÖRÜ |
| MAKTEK EPSİLON | F6 | SICAK SU SENSÖRÜ |
| MAKTEK EPSİLON | F12 | SICAK SU SENSÖRÜ |
| MAKTEK RUBY | E1 | FAN PROSESTAT |
| MAKTEK RUBY | E2 | KALORİFER SENSÖR |
| MAKTEK RUBY | E3 | SICAK SU SENSÖR |
| MAKTEK RUBY | E4 | AŞIRI ISI LİMİT |
| MAKTEK RUBY | E6 | GAZ VALFİ HATASI |
| MAKTEK RUBY | E7 | İYONİZASYON |
| MAKTEK RUBY | EP | SENSÖR HATASI |
| PROTHERM LEOPARD (LEDLİ) | 40 | C SICAK SU SENSÖRÜ |
| PROTHERM LEOPARD (LEDLİ) | 50 | C FAN PROSESTAT |
| PROTHERM LEOPARD (LEDLİ) | 60 | C AŞIRI ISI LİMİT |
| PROTHERM LEOPARD (LEDLİ) | 70 | C İYONİZASYON |
| PROTHERM LEOPARD (LEDLİ) | 80 | C SİRKÜLASYON BASINÇ |
| PROTHERM LEOPARD (LEDLİ) | 70 | C – 80 CSİRKÜLASYON BASINÇ |
| PROTHERM LEOPARD (LEDLİ) | 60 | C – 80 CVOLTAJ HATASI |
| PROTHERM LEOPARD (LEDLİ) | 50 | C – 80 CGAZ VALFİ HATASI |
| PROTHERM LEOPARD | F1 | LİMİT – VALF – ATEŞLEME TRAFO |
| PROTHERM LEOPARD | F2 | KALORİFER NTC |
| PROTHERM LEOPARD | F3 | LİMİT – POMPA |
| PROTHERM LEOPARD | F4 | SICAK SU NTC |
| PROTHERM LEOPARD | F5 | YANLIŞ İYONİZASYON |
| PROTHERM LEOPARD | F6 | FAN PROSESTAT |
| PROTHERM LEOPARD | F7 | İLETİŞİM HATASI |
| PROTHERM LEOPARD | F8 | GAZ VALFİ HATASI |
| PROTHERM LEOPARD | F9 | PARAMETRE DEĞERLERİNİN KAYBI |
| PROTHERM LYNX | F01 | AŞIRI ISI |
| PROTHERM LYNX | F02 | SICAK SU NTC |
| PROTHERM LYNX | F03 | KALORİFER GİDİŞ NTC |
| PROTHERM LYNX | F04 | İYONİZASYON |
| PROTHERM LYNX | F05 | PROSESTAT KONTAKLARI KAPANMIYOR |
| PROTHERM LYNX | F06 | KALORİFER DÖNÜŞ NTC |
| PROTHERM LYNX | F07 | GAZ VALFİ ARIZASI |
| PROTHERM LYNX | F08 | AŞIRI ISI VE KALORİFER GİDİŞ NTC |
| PROTHERM LYNX | F09 | PROSESTAT KONTAKLARI AÇIK KALMIŞ |
| PROTHERM LYNX | F10 | SU BASIN HATASI |
| PROTHERM LYNX | F11 | SİRKÜLASYON HATASI |
| PROTHERM LYNX | F12 | DÜŞÜK VOLTAJ HATASI |
| PROTHERM LYNX | F13 | KALORİFER NTC’LERİ HATASI |
| PROTHERM LYNX | F88 | NTC SENSÖR |
| PROTHERM PANTER | F1 | İYONİZASYON – LİMİT |
| PROTHERM PANTER | F2 | KALORİFER SENSÖRÜ |
| PROTHERM PANTER | F3 | AŞIRI ISI LİMİT |
| PROTHERM PANTER | F5 | DIŞ HAVA SENSÖRÜ |
| PROTHERM PANTER | F1 | KALORİFER DÖNÜŞ NTC F61 GAZ VALFİ HATASI |
| PROTHERM PANTER | F11 | KALORİFER DÖNÜŞ NTC F63 İŞLEMCİ HATASI |
| PROTHERM PANTER | F20 | AŞIRI ISI LİMİT F64 ANA KART HATASI |
| PROTHERM PANTER | F22 | KURU YANMA – SİRKÜLASYON F65 ANA KART HATASI |
| PROTHERM PANTER | F23 | YETERSİZ SİRKÜLASYON F66 ANA KART EKRAN KARI İLETİŞİM |
| PROTHERM PANTER | F24 | YETERSİZ SİRKÜLASYON F67 İYONİZASYON |
| PROTHERM PANTER | F25 | BACA SENSÖRÜ F70 ANA KART EKRAN KARI İLETİŞİM |
| PROTHERM PANTER | F26 | VALF STEP MOTOR HATASI F71 TÜRBİN HATASI |
| PROTHERM PANTER | F27 | İYONİZASYON F72 KALORİFER SENSÖRLERİ HATASI |
| PROTHERM PANTER | F28 | GAZ VALFİ – KART F73 BASINÇ SENSÖRÜ HATASI |
| PROTHERM PANTER | F29 | İYONİZASYON F74 BASINÇ SENSÖRÜ HATASI |
| PROTHERM PANTER | F33 | FAN PROSESTAT HATASI F75 BASINÇ SENSÖRÜ HATASI |
| PROTHERM PANTER | F49 | e BUS HABERLEŞME HATASI Er ANA KART EKRAN KARI İLETİŞİM |
| PROTHERM PANTER | F57 | ANA KART HATASI |
| PROTHERM PANTER | F1 | İYONİZASYON |
| PROTHERM PANTER | F2 | AŞIRI ISI LİMİT |
| PROTHERM PANTER | F4 | SU BASINÇ HATASI |
| PROTHERM PANTER | F5 | KALORİFER SENSÖRÜ |
| PROTHERM PANTER | F6 | SICAK SU SENSÖRÜ |
| PROTHERM PANTER | F12 | SICAK SU SENSÖRÜ |
| TERMOTEKNİK TERMOSLİM | E1 | SU BASINCI |
| TERMOTEKNİK TERMOSLİM | E2 | ALEV İYONİZASYON |
| TERMOTEKNİK TERMOSLİM | E3 | KALORİFER SENSÖRÜ |
| TERMOTEKNİK TERMOSLİM | E4 | SICAK SU SENSÖRÜ |
| TERMOTEKNİK TERMOSLİM | E5 | FAN PROSESTAT |
| TERMOTEKNİK TERMOSLİM | E6 | AŞIRI ISI LİMİT |
| TERMOTEKNİK TERMOSLİM | E7 | VOLTAJ HATASI |
| TERMOTEKNİK TERMOSLİM | E8 | AŞIRI ISI LİMİT |
| TERMOTEKNİK TERMOSLİM | E9 | ARIZA KİTLEMESİ |
| TERMOTEKNİK LOGİC | F6 | DIŞ HAVA SENSÖRÜ |
| TERMOTEKNİK LOGİC | F7 | VOLTAJ HATASI |
| TERMOTEKNİK LOGİC | F9 | ANA KART HATASI |
| TERMOTEKNİK LOGİC | L5 | YENİDEN BAŞLAMA HATASI |
| TERMOTEKNİK LOGİC | L6 | İYONİZASYON |
| TERMOTEKNİK LOGİC | C2 | BCC HATASI |
| TERMOTEKNİK LOGİC | F1 | SU BASINÇ |
| TERMOTEKNİK LOGİC | L1 | AŞIRI ISI LİMİT |
| TERMOTEKNİK LOGİC | F2 | ALEV KAYBI |
| TERMOTEKNİK LOGİC | L2 | ATEŞLEME YOK |
| TERMOTEKNİK LOGİC | F3 | FAN HATASI |
| TERMOTEKNİK LOGİC | F4 | KALORİFER GİDİŞ SENSÖR |
| TERMOTEKNİK LOGİC | F5 | KALORİFER DÖNÜŞ SENSÖR |
| VAİLLANT VUV PLUS | F1 | KALORİFER DÖNÜŞ NTC F49 e BUS HABERLEŞME HATASI |
| VAİLLANT VUV PLUS | F11 | KALORİFER DÖNÜŞ NTC F60 GAZ VALFİ HATASI |
| VAİLLANT VUV PLUS | F13 | BOYLER SENSÖRÜ F61 GAZ VALFİ HATASI |
| VAİLLANT VUV PLUS | F20 | AŞIRI ISI LİMİT F62 GAZ VALFİ HATASI |
| VAİLLANT VUV PLUS | F22 | KURU YANMA – SİRKÜLASYON F63 İŞLEMCİ HATASI |
| VAİLLANT VUV PLUS | F23 | YETERSİZ SİRKÜLASYON F64 ANA KART HATASI |
| VAİLLANT VUV PLUS | F24 | YETERSİZ SİRKÜLASYON F65 ANA KART HATASI |
| VAİLLANT VUV PLUS | F25 | BACA SENSÖRÜ F66 ANA KART EKRAN KARI İLETİŞİM |
| VAİLLANT VUV PLUS | F26 | VALF STEP MOTOR HATASI F67 İYONİZASYON |
| VAİLLANT VUV PLUS | F27 | İYONİZASYON F70 ANA KART EKRAN KARI İLETİŞİM |
| VAİLLANT VUV PLUS | F28 | GAZ VALFİ – KART F71 TÜRBİN HATASI |
| VAİLLANT VUV PLUS | F29 | İYONİZASYON F72 KALORİFER SENSÖRLERİ HATASI |
| VAİLLANT VUV PLUS | F32 | FAN PROSESTAT HATASI F73 BASINÇ SENSÖRÜ HATASI |
| VAİLLANT VUV PLUS | F33 | FAN PROSESTAT HATASI F74 BASINÇ SENSÖRÜ HATASI |
| VAİLLANT VUV PLUS | F37 | FAN PROSESTAT HATASI F75 BASINÇ SENSÖRÜ HATASI |
| VAİLLANT VUV PLUS | F42 | KODLAMA DİRENCİ K.D Er ANA KART EKRAN KARI İLETİŞİM |